Section 27-301
§ 27-301 Area limitations of buildings. No building or building
section shall be constructed or altered so as to exceed the area limits
established by tables 4-1 and 4-2 based on the occupancy group
classification of the building or building section, except as these may
be specifically modified by other provisions of this code.
Section 27-302
§ 27-302 Area limitations of spaces. No occupancy within a building or
building section shall be constructed or altered so as to exceed in
total cumulative area the area limits established by tables 4-1 and 4-2,
except as these may be specifically modified by other provisions of this
code.
Section 27-303
§ 27-303 Frontage increase. When a building has more than twenty-five
per cent of the total perimeter of the building fronting directly upon a
street or frontage space, the tabular areas listed in tables 4-1 and 4-2
may be increased 1.33 per cent for each one per cent of such excess
frontage.
Section 27-304
§ 27-304 Existing excessive area. Any building existing on December
sixth, nineteen hundred sixty-eight that exceeds the maximum allowable
area permitted under the provisions of this section, may be enlarged if
the addition is separated from the existing building by a fire division
meeting the requirements of subchapter five of this chapter, and if the
additional area does not exceed the limits established by tables 4-1 and
4-2 for the specific occupancy group and construction class.