Article 7 - HEIGHT LIMITATIONS

Section 27-305

Section 27-305

  §  27-305  Height  limitations  of  buildings. No building or building
section shall be constructed or altered  so  as  to  exceed  the  height
limits  established  by  tables 4-1 and 4-2 based on the occupancy group
classification of the building or building section, except as these  may
be specifically modified by other provisions of this code.

Section 27-306

Section 27-306

  §  27-306  Measurement.  In  applying  the  provisions  of  this  code
governing height limits, the following appurtenant structures shall  not
be  included  in the height of the building unless the aggregate area of
all such structures, exclusive of any solar thermal and  solar  electric
(photovoltaic)  collectors and/or panels and their supporting equipment,
exceeds thirty-three and one-third percent of the area of  the  roof  of
the building upon which they are erected:
  (a) Roof tanks and their supports.
  (b)  Ventilating,  air  conditioning, combined heat and power systems,
and similar building service equipment.
  (c) Roof structures, bulkheads, and penthouses.
  (d) Chimneys.
  (e) Parapet walls four feet or less in height.

Section 27-306.1.

Section 27-306.1.

  §   27-306.1.   Measurement;   solar   thermal   and   solar  electric
(photovoltaic) collectors and/or panels and their supporting  equipment.
Notwithstanding  any  inconsistent  provision  of section 27-306 of this
code, solar thermal and solar electric (photovoltaic) collectors  and/or
panels  and  their  supporting  equipment  that  exceed 33 and one-third
percent of the area of the roof of the  building  upon  which  they  are
erected  shall not be included in the height of a building or considered
an additional story.