Article 9 - AUTOMOTIVE REPAIR SHOPS

Section 27-443

Section 27-443

  §  27-443  Application.  This section shall apply to the construction,
alteration, and use of buildings or spaces as automotive repair shops.

Section 27-444

Section 27-444

  §  27-444  Classification. Automotive repair shops shall be classified
in industrial occupancy group D-1.

Section 27-445

Section 27-445

  §  27-445 Volatile flammables. All volatile flammables shall be stored
and handled in accordance with the provisions of chapter  four  of  this
title.

Section 27-446

Section 27-446

  § 27-446 Ventilation. All spaces used for the repair of motor vehicles
shall  be  provided with mechanical ventilation adequate to provide four
air changes per hour.
  (a) Exhaust gases. Where engines are to be run for  test  purposes  or
adjustments,  provisions shall be made to collect the exhaust gases from
each vehicle and to discharge such gases to the outer air by means of  a
positively  induced  draft. The discharge opening from such system shall
be located as required by subchapter thirteen of this chapter.
  (b) Pits. All pits for inspection  or  repair  shall  have  mechanical
exhaust  ventilation taken from near the bottom of the pits. Pit exhaust
systems shall be adequate to provide at least four air changes per hour.

Section 27-447

Section 27-447

  § 27-447 Sprinklers. Automatic sprinkler protection complying with the
construction provisions of subchapter seventeen of this chapter shall be
provided as required by occupancy group D-1.

Section 27-448

Section 27-448

  §  27-448  Heating equipment. Heat generating equipment for automotive
repair shops shall be enclosed in accordance with  the  requirements  of
section 27-419 of article five of this subchapter.

Section 27-449

Section 27-449

§ 27-449 Pits. All pits shall be provided with two means of egress.